Feature
Specification Rating
High flow purge gas
Air, nitrogen or other inert
gas which is compatible with
the process
Typically 185 slm at at-
mospheric pressure at
the purge inlet connec-
tion
High flow purge air filter
1/2 inch NPT male
(available as a spare, refer
to Table: Spares)
DP clean solvent flush
fluid inlet connection
3/8 inch BSP male
DP clean solvent suc-
tion pipe connection
3/8 inch BSP female
Note:
The DP clean solvent suction pipe is supplied with the pump but not fitted. Refer
to the instruction given with the kit to activate the function.