Installation Manual 48 Document #: LTRT-10205
Mediant 800 MSBG
2. Under the 'QoS Output Rules' table, click the New
button corresponding to 'WAN
Ethernet Rules'; the following page appears:
Figure 3-19: QoS Output Traffic Matching Rules
3. Add a new output traffic matching rule for VoIP SIP signaling to the WAN:
a. From the 'Protocol' drop-down list, select 'SIP'; “SIP” is displayed under the
’Protocol’ group.
b. From the drop-down list appearing below “SIP”, select 'User Defined'; the
following appears.
Figure 3-20: Defining Incoming SIP Ports
c. In the 'Service Name' field, enter the service, for example, “SIP”, and then click
New Server Ports; the following page appears.