3.2.1.6 Enabling Remote HTTP/S Web Management
If you want to access the device’s Web interface remotely through HTTP or HTTPS, you
need to define the WAN HTTP/S port.
¾ To define WAN HTTP/S port for remote Web management:
1. Open the 'WEB Security Settings' page (Configuration tab > System menu >
Management submenu > WEB Security Settings).
Figure 3-25: Defining WAN HTTP Port
2. In the ‘WAN HTTP Port’ or ‘WAN HTTPS Port’ field, define the WAN port.
3. Click Submit.
3.2.2 VoIP-only Functionality
If you wish to use the device only as a VoIP gateway (i.e., without data-routing
functionality), you need to disable the data-routing interface as described in the procedure
below.
Note: When operating in VoIP-only mode, do not use the device’s WAN port.
¾ To operate the device as a VoIP gateway only:
1. Disconnect the network cable from the WAN port and then connect one of the device’s
LAN ports to the network.
2. Disable or remove the data-routing IP network interface:
a. Access the ‘Connections’ page (Configuration tab > Data menu > Data System
> Connections).
b. Delete the “LAN Switch VLAN 1” connection by clicking the corresponding
Remove
button, and then clicking OK to confirm deletion.
Figure 3-26: Removing Data-Routing Connection Interface