- INSTALLER HIGHTEMPERATURE ENERGY EFFICIENT HEAT PUMP MANUAL-
33
Enter turn
Enter
turn
turn
Enter
Enter
Enter
Enter
Enter
setting AMBIeNCE
ECO
DHw set
swim. pool
anti freez
boost
summ./WINT.
language
beep
inst. menu
Switch to Boost mode
Switch to summer / winter
mode
Change language
Beep activated when dial
pressed
Access installer menu
N.B: When the circuit(s) are controlled by a thermostat
(ou aquastat for domestic hot water), the Setting sub-menu will
not appear.
N.B: When 2 circuits are used for heating and each one
has a room temperature sensor, the setting sub-menu o ers the
following options:
ambience 1 ambience 2 eco 1 eco 2 anti freez 1 anti freez 2
N.B: The temperature sensor is connected and the parametres set.
5.3.1 - Setting target temperatures
5.3.1.3 - Setting the anti freez target
temperature
anti freez
7.0°C
by default
anti freez
8.0°C
example
Enter
Enter
anti freez
N.B : Only where there is a room temperature sensor and
display
turn to
modify
target
temperature
turn to go to
next setting,
dhw set
anti freez
ambience
20.0°C
by default
ambience
22.0°C
example
Enter
Enter
AMBIeNCE
5.3.1.1 - Setting the AmbiEnce target
temperature
5.3.1.2 - Setting the eco target temperature
N.B: Only when there is a room temperature sensor and display
on circuit 1.
turn to
modify
target
temperature
turn to go to
next setting,
ECO
ambience
ECO
17.0°C
by default
ECO
16.0°C
example
Enter
Enter
ECO
N.B: Only when there is a room temperature sensor and a
display
turn to
modify
target
temperature
turn to go
to next
setting,
anti
freeze
ECO

Table of Contents