AUX air conditioner service manual
69
left grid runs-grid stops-up and down grid runs-grid stops-up and down, right and left grid runs,
and the corresponding indication light of “up and down grid, right and left grid” twinkles; If don’t
press the “Swing” button, the corresponding indication light of “up and down grid, right and left grid”
shines constantly.
b) When the indoor fan stops, the air grid stops; When the indoor fan runs, the air grid runs;
c) The working conditions of the air grid remain invariable when the working mode of the
air-conditioner is transformed or the restart without non-electricity;
⑤“plus”button
a)The “plus”button can increase the setting temperature, and the setting range is 16℃—32℃;
b)The button is invalid when the setting temperature is 32℃;
c)The button is invalid when the mode is ventilation.
d)Press and last for 3 seconds for acceleration.
⑥“minus” button
a)The “minus” button can decrease the setting temperature, and the setting range is 16℃—32℃;;
b)The button is invalid when the setting temperature is 16℃;
c)The button is invalid when the mode is ventilation.;
d)Press and last for 3 seconds for acceleration.
⑦“lock” button
Press the “plus” and “minus” buttons simultaneously and last for 3 seconds or more , the
corresponding “lock” symbol on the numerical tube screen light on. At this moment, there is no
response from the tube screen to any other buttons being pressed as well as the signal from the remote
controller. Under the “lock” condition, if press the “plus” and “minus” buttons simultaneously and last
for 3 seconds or more, the “lock” symbol on the numerical tube screen turns off and resumes to the
normal condition.
T⑵ he button functions of the remote controller
The functions of “on/off” button and the “fan speed” button on the remote controller are in accordance
with the functions of the corresponding buttons of the control panel.
①“timing” button
a) When the air-conditioner turns on, the timing close function can be set by pressing the “timing”
button if there is no time setting. It enters the time regulatory setting moment and the primary setting
is six hours. Press the “plus” or “minus” button on the remote controller can set the timing close time
(1~24h), and the minimum setting time is one hour. Repress the “timing” button for confirming the
setting time, and the air-conditioner starts the timing close function. The double “8” on the panel used
for showing the indoor temperature is displaying the indoor temperature and the balanced time of the
setting close time by returns. The interval cycle between the two displays is 5 seconds, and the
minimum time unit for display is 1 hour. When the timing close time is over, the air-conditioner turns
off automatically and the timing close function is cancelled.