EasyManuals Logo

Azbil JTD910S User Manual

Azbil JTD910S
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
1-3
Chapter 1 Functionality, Configuration, and Structure of this Device and CommStaff
Main unit: Composed of a compound semiconductor sensor, an A/D
circuit, a pressure-receiving diaphragm, an excess pressure
protection mechanism, etc.
Cover flanges: Parts which sandwich the sides of the main unit to maintain
pressure.
Adapter flanges: Used attached to the cover flanges. Connected to connecting
pipes.
Bolts and nuts: Used in interposing the main unit between the cover flanges.
Vent/drain plug: Used when clearing the vents and drains.
Flange: In the JTC, JTE, and JTH models, used along with the opposing
process flange to sandwich the diaphragm base.
Diaphragm base: In the JTC, JTE, and JTH models, receives the measured
pressure.
Capillary tube: In the JTE and JTH models, connects the main unit and the
diaphragm base.
Electronics module: Electronic circuit which processes and transmits differential
pressure signals etc.
Flexible cable: Part which electrically connects the main unit and the
electronics module.
Transmission unit case: Houses the electronics module, terminal block, etc.
Case cover: Cover for sealing the transmission unit case.
Terminal block
with integrated indicators:
Terminals to which to connect electrical signals.
CommStaff can also be connected here. The indicators are
optional.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Azbil JTD910S and is the answer not in the manual?

Azbil JTD910S Specifications

General IconGeneral
BrandAzbil
ModelJTD910S
CategoryTransmitter
LanguageEnglish

Related product manuals