Operation using the data setting device Azbil Corporation
5-42 Model MTG11A/18A, MTG11B/18B, MTG14C
5-6-2 : Selecting Pulse Output, Electrode Status Output or High
Low Status Output
Pulse output, electrode status output or high low status output are selectable. They are
open collector outputs.
When pulse output has been selected:
Set pulse scale, pulse width, drop out, and failsafe mode for the pulse
output.
When high low status output has been selected:
As a contact output, self diagnostic output (critical failure) or upper/lower
limit alarm is output.
Select % flow rate value for upper/lower alarm or output status (OPEN or
CLOSE in normal condition).
When electrode status output has been selected:
As a contact output, empty status output or scale on electrode status alarm
is output.
Select output status (OPEN or CLOSE in normal condition).
Setting range: PULSE: Selection of pulse output
HI LO STOUT: Selection of contact output for upper/lower limit alarm
or critical failure status
ELECTRODE STOUT: Selection of contact output for empty status or
scale on electrode diagnostic
Default: PULSE
Select pulse output, electrode status output or high low status output in accordance
with the following procedure.
Step Procedure Screen
1
Enter ENGINEERING MODE (see “Entering
Engineering Mode and Maintenance Mode” on
page 5-36). Then press the
or key to display the
screen at right.
2 Press the key to move the cursor to the position
for set function.
Press the or key to display a function to be set.
Select PULSE (pulse output), HI LO STOUT
(contact output for upper/lower limit alarm or
critical failure status) or ELECTRODE STOUT
(contact output for empty status or scale on electrode
diagnostic).
20.0 %
_
# FUNC SET
PULSE
20.0 %
# FUNC SET
_
PULSE
20.0 %
# FUNC SET
_
HI LO STOUT
20.0 %
# FUNC SET
_
ELECTRODE STOUT