EasyManuals Logo

Banner AG4 Series User Manual

Banner AG4 Series
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
Banner AG4 Series Safety Laser Scanner
Place
Number
Meaning
Activity
1906
2
Safety outputs or switching function (OSSDs) cannot
be switched, internal or external short-circuit.
Check the connection/wiring of the OSSDs. If reset is not successful,
contact customer service
1906
5
Read back error on the safety outputs or switching
function (OSSDs), internal or external short-circuit.
Check the connection/wiring of the OSSDs. If reset is not successful,
contact customer service
1906
6
Error on the laser's switch-off path, switch-off because
of eye safety, internal defect
If reset is not successful, contact customer service
1907
4
Angle error detected, poss. rotation of the sensor
housing; switch-off and reset followed.
If reset is not successful, contact customer service
1907
7
Angle error detected, poss. rotation of the sensor
housing; switch-off and reset followed.
If reset is not successful, contact customer service
2002
12
The configuration data displayed for the check was not
acknowledged for too long.
Start the transfer again.
2007
18
Date of the Protective Field currently being transferred
is older than the date saved in the Scanner.
Update the PC's date and time setting.
2017
19
Data transfer error with ConfigPlug
Replace the ConfigPlug or the complete cable with plug.
2017
23
The connected Scanner does not support the
configuration file in the ConfigPlug.
Change the Scanner, observe the device type.
2017
24
The connected Scanner does not support the
configuration file in the ConfigPlug.
Change the Scanner, observe the device type.
2017
26
Date of the configuration currently being transferred is
older than the date saved in the Scanner.
Update the PC's date and time setting.
2018
42
Motion Monitoring, error with the speed matrix transfer.
Start the configuration transfer again.
2018
43
Motion Monitoring, error with the speed matrix transfer.
Start the configuration transfer again.
2018
44
Motion Monitoring, the right side of a Protective Field
does not match the predefined vehicle width.
Check all parameters in the wizard, calculate the Protective Fields again
and start the transfer again.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com

Table of Contents

Other manuals for Banner AG4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Banner AG4 Series and is the answer not in the manual?

Banner AG4 Series Specifications

General IconGeneral
BrandBanner
ModelAG4 Series
CategoryScanner
LanguageEnglish

Related product manuals