The range bar at the bottom of the screen provides a zoomed view of the range so that you can fine-tune the range. Click on the bar
and drag up to bring up the zoomed view as shown below.
Pass Count (Blemish)
The sensor aggregates all the edge pixels that fall within the Edge Length Range and indicates the value with a small colored bar at the
bottom of the Pass Count page. If within the range brackets, the bar is green, otherwise it is yellow. The brackets can be used to set a
tolerance for pass/fail.
Main Menu > Inspection > Blemish > Pass Count
3.4.4 Motion Parameters (Optionally Available for Area and Blemish)
Motion settings involve selecting the number of edges to locate, adjusting sensitivity, and selecting whether or not rotation is enabled.
Main Menu > Inspection > Motion