4-4
CLM W6_CLM HD6 Jan 31, 2012
Chapter 4 Function Test & Alignment Procedure
Order Symptom Pattern Criteria
1 Bright pixel ( dots) Gray 10 pattern
A+B=0 (CLM HD6)
A+B≤1 (CLM W6)
2 Dark pixel(dots) White pattern A+B ≤ 6
3 Bright blemish Gray 15 pattern A+B ≤ 10
4 Dark blemish Blue 60 pattern A+B ≤ 10
5 Bright dot on frame Gray 10 pattern ≤ 1
6 Unstable pixel White & Black pattern A+B ≤ 1
7 Adjacent dark pixel White & Black pattern A+B = 0
Defect specication spec.
< Figure: Zone A--> The blue area which in the center of the image;
Zone B--> The white area which between green line and blue area;
Frame--> The green line;
Denition, Active area = Zone A + Zone B >