4-10
CLM W6_CLM HD6 Jan 31, 2012
Chapter 4 Function Test & Alignment Procedure
2. F-type Fan Calibration
Procedure - Put the projector on a horizontal surface.
- Plug in Power, and keep projector in power off mode.
- Push "Up (+)" key and hold it (refer to mark 1).
- Turn on the power switch (refer to mark 2)
- Push "STBY" key and then projector lamp turn on
(refer to mark 3).
- When the projector has displayed the image, and then
release "Up (+)" key.
- When the led of "Temp" is ashing, that means Fan
calibration is starting.
- When the projector turns to "Standby" mode, that
means Fan calibration is nished.