EasyManua.ls Logo

Barco CLM W6 - Page 89

Barco CLM W6
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-10
CLM W6_CLM HD6 Jan 31, 2012
Chapter 4 Function Test & Alignment Procedure
2. F-type Fan Calibration
Procedure - Put the projector on a horizontal surface.
- Plug in Power, and keep projector in power off mode.
- Push "Up (+)" key and hold it (refer to mark 1).
- Turn on the power switch (refer to mark 2)
- Push "STBY" key and then projector lamp turn on
(refer to mark 3).
- When the projector has displayed the image, and then
release "Up (+)" key.
- When the led of "Temp" is ashing, that means Fan
calibration is starting.
- When the projector turns to "Standby" mode, that
means Fan calibration is nished.

Table of Contents

Other manuals for Barco CLM W6

Related product manuals