EasyManua.ls Logo

Barco PDS - Ihpan; Ihpos; Ihtotal; Ihue

Barco PDS
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PDS • User’s Guide 131
_K==oÉãçíÉ=`çåíêçä
Remote Commands
fem^k=
Description: Input Horizontal Pan
Command Format: IHPAN -i (input) -p (pan)
Parameters:
-i (input): 1 - 9
-p (pan): In pixels
Query Format: IHPAN -i (input) -?
Query Response: IHPAN -i (input) -p (pan) --min (active min) -- max (active
max)
femlp
Description: Input Horizontal Position Adjust. This command is only adjustable
for analog input types. Other input types will provide query information only.
Command Format: IHPOS -i (input) -p (position)
Parameters:
-i (input): 1 - 8 for adjustments (5 - 8 only if itype is analog); 1 - 9 for
query
-p (position): In pixels
Query Format: IHPOS -i (input) -?
Query Response:
IHPOS -i (input) -p (position) --min (pos min) -- max (pos max)
feqlq^i
Description: Input Horizontal Total Adjust. This command is only adjustable for
analog input types. Other input types will provide query information only.
Command Format: IHTOTAL -i (input) -t (total)
Parameters:
-i (input): 1 - 8 for adjustments (5 - 8 only if itype is analog); 1 - 9 for
query
-t(total): In pixels
Query Format: IHTOTAL -i (input) -?
Query Response: IHTOTAL -i (input) -t (total) --min (total min) -- max (total max)
ferb
Description: Input Hue Adjust. This command is only valid for analog, Y/C and
CVBS inputs.
Command Format: IHUE -i (input) -h (hue)
Parameters:
-i (input): 1 - 9
-h (hue): -90 - +90 (Default: 0)
Query Format: IHUE -i (input) -?