PDS • User’s Guide 147
_K==oÉãçíÉ=`çåíêçä
Remote Commands
Parameters:
-b (baud): 0 - 9600, 1 - 38400, 2 - 57600, 3 - 115200 (default: 115200)
-p (parity/etc): 0 - N81, 1 - E71, 2 - O71, 3 - E72, 4 - O72 (default: N81)
-h (handshaking): 0 - off, 1 - on (default: off)
Query Format: SERIAL -? - (option letter)
The SERIAL query will return only one option parameter at a time. If no
option is specified, an error code will be returned.
Query Response: SERIAL -b (baud) --min 0 -- max 3
SERIAL -p (psarity/etc) --min 0 -max 4
SERIAL -h (handshaking) --min 0 -max 1
qbjm
Description: Query only command for the temperature of the unit.
Query Format: TEMP -?
Query Response: TEMP -a (sensor addr) -c (celsius) -f (fahrenheit)
qokqfjb=
Description: Set transition time
Command Format: TRNTIME -s (seconds)
Parameters: -s (seconds): 0 - 12.0 (default 1.0)
Query Format: TRNTIME -?
Query Response: TRNTIME -s (seconds) --min 0 --max 12.0
rkfqfa=
Description: Encore unit ID
Command Format:UNITID –i (unit ID)
Parameters: -i (unitID): 1 - 32
Query Format: UNITID –i (input) -?
Query Response: UNITID –i (unitID) --min 1 --max 32
sbo
Description: Display Version info
Command Format: VER
Parameters: N/A
Query Format: N/A
Query Response: N/A
sca_oq=
Description: Set VFD brightness
Command Format: VFDBRT -b (brightness) -f