134 PDS • User’s Guide
_K==oÉãçíÉ=`çåíêçä
Remote Commands
fpfwbopq
Description: Reset the input sizing parameters to default values
Command Format: ISIZERST -i (input)
Parameters: -i (input): 1 - 6 and 9 (PDS-701); 1 - 9 (PDS-901/902)
Query Format: N/A
Query Response: N/A
fpif`b=
Description: Input Sync Slice Threshold Adjust. This command is only valid for
analog inputs.
Command Format: ISLICE -i (input) -t (threshold)
Parameters:
-i (input): 1 - 8 for adjustments (5 - 8 only if itype is analog)
-t(threshold): 8 - 256mV; +8 increments (default: 128mV)
Query Format: ISLICE -i (input) -?
Query Response: ISLICE -i (input) -t (threshold) --min 8 -- max 256
fpjm=
Description: Adjust Input Sample mode. This command is only adjustable for
analog input types. Other input types will provide query information only.
Command Format: ISMP -i (input) -s (sample mode)
Parameters:
-i (input): 1 - 8 for adjustments (5 - 8 only if itype is analog); 1 - 9 for
query
-s (sample mode): 0 - 1:1 sampling off, 1 - 1:1 sampling on (Default: On)
Query Format: ISMP -i (input) -?
Query Response: ISMP -i (input) -s (sample mode) --min 0 -- max 1
List Format: Each input type has a different list of valid sample modes.
ISMP -i (input) --list
List Response:
0:"Off"
1:"On"
fpvk`
Description: Input Sync Type Adjust. This command is only valid for analog
input types.
Command Format: ISYNC -i (input) -s (sync)
Parameters:
-i (input): 1 - 8 (5 - 8 only if itype is analog)
-s (sync): 0 - auto, 1 - H/V, 2- CSync, 3- SOG (Default: auto)