146 PDS • User’s Guide
_K==oÉãçíÉ=`çåíêçä
Remote Commands
Parameters:
-i (input): 1 - 9
-b: black on preview
-l: logo on preview
-a: A or B path of scaler input on preview
Query Format: PREVIEW -?
Query Response: PREVIEW -i(input) -k -b
moldo^j=
Description: Query only command for the input and black button status on
program. If the black or scaler path is not present on program, then these options
are not returned.
Parameters:
-i (input): 1 - 9
-b: black on preview
-l: logo on preview
-a: A or B path of scaler input on preview
Query Format: PROGRAM -?
Query Response: PROGRAM -i(input) -k -b
obpbq
Description: Reset unit
Command Format: RESET [-f | -s ]
Parameters:
-f : factory reset
or
-s: soft reset
Query Format: N/A
Query Response: N/A
p^sb=
Description: System Save
Command Format: SAVE
Parameters: N/A
Query Format: N/A
Query Response: N/A
pbof^i=
Description: Sets the serial port.
Command Format: SERIAL -b (baud) -p (parity/etc.) -h (handshaking)

Table of Contents