PDS • User’s Guide 135
_K==oÉãçíÉ=`çåíêçä
Remote Commands
• Query Format: ISYNC -i (input) -?
• Query Response: ISYNC -i (input) -s(sync) --min 0 --max 3
• List Format: ISYNC -i (input) --list
• List Response:
0:"Auto"
1:"H/V"
2:"CSync"
3:"SOG"
fqvmb
• Description: Input Type Adjust. This command is only adjustable for the analog
inputs. Other inputs will provide query information only.
• Command Format: ITYPE -i (input) -t (type)
• Parameters:
-i (input): 1 - 8 for adjustments (5 - 8 only if itype is analog) ; 1 - 9 for
query
-t (type): 1-analog, 2-Y/C, 3-CVBS, 4-SDI, 5-DVI, 6-YPbPr
• Query Format: ITYPE -i (input) -?
• Query Response: ITYPE -i (input) -t (type)
• List Format: Each input type has a different list of valid input types.
ITYPE -i (input) --list
• List Response:
1:"RGB"
2:"Y/C"
3:"CVBS"
4:"SDI"
5:"DVI"
6:"YPBPR"
fs^qs
• Description: Input Vertical Active Adjust. This command is only adjustable for
analog input types. Other input types will provide query information only.
• Command Format: IVATV -i (input) -a (active)
• Parameters:
-i (input): 1 - 8 for adjustments (5 - 8 only if input is analog); 1 - 9 for
query
-a (active): In lines
• Query Format: IVATV -i (input) -?
• Query Response: IVATV -i (input) -a (total) --min (active min) -- max (active max)