Image Data Formats & Structures
5-4 BASLER A102
f
DRAFT
5.3.2 Data Format with the Camera Set for Y Mono 8 Output
The table below describes how the data for a received frame will be ordered in the image buffer
in your PC.
The following standards are used in the table:
P
0
= the first pixel transmitted by the camera
P
n
= the last pixel transmitted by the camera
B
0
= the first byte in the buffer
B
m
= the last byte in the buffer
Byte Data
B
0
Y value for P
0
B
1
Y value for P
1
B
2
Y value for P
2
B
3
Y value for P
3
B
4
Y value for P
4
B
5
Y value for P
5
B
6
Y value for P
6
B
7
Y value for P
7
••
••
••
B
m-3
Y value for P
n-3
B
m-2
Y value for P
n-2
B
m-1
Y value for P
n-1
B
m
Y value for P
n

Table of Contents