Smart Features
BASLER A102
f 6-13
DRAFT
6.7.4 DCAM Values
The DCAM values feature adds a chunk to each image frame containing the current settings for
some standard DCAM features. The settings are sampled at the start of exposure of each image.
Control and Status Register for the DCAM Values Feature
L
The extended data stream feature (see Section 6.7.1) must be enabled in order to
use the DCAM values feature or any of the other smart feature that adds information
to the image data stream. Disabling the extended data stream feature switches off all
smart features that add information to the image data stream.
The DCAM values feature will only work when the camera is set for video format 7.
Name DCAM Values
Address See “Determining the Address of Smart Features CSRs” on page 6-4.
CSR GUID 494DE528 - 1B84 - 11D8 - 8A0C - 00105A5BAE55
Field Bit Description
Presence Inq
(Read only)
[0] Presence of this feature
0: Not Available 1: Available
---- [1 ... 30] Reserved
Enable
(Read / write)
[31] Enable / Disable this feature
0: Disable 1: Enable