AW00123402000 Image Acquisition Control
Basler ace USB 3.0 99
6.4 The Frame Start Trigger
The frame start trigger is used to begin frame acquisition. Assuming that the camera is in a "waiting
for frame start trigger" acquisition status, it will begin a frame acquisition each time it receives a
frame start trigger signal.
Note that in order for the camera to be in a "waiting for frame start trigger" acquisition status:
The Acquisition Mode parameter must be set correctly.
A proper Acquisition Start command must be applied to the camera.
A proper frame burst start trigger signal must be applied to the camera (if the Trigger Mode
parameter for the frame burst start trigger is set to on).
For more information about the Acquisition Mode parameter and about Acquisition Start and
Acquisition Stop commands, see Section 6.1 on page 85 and Section 6.2 on page 89.
For more information about the frame burst start trigger, and about the acquisition status, see
Section 6.1 on page 85 and Section 6.3 on page 91.
Referring to the use case diagrams that appear in Section 6.9 on page 141 can help you
understand the explanations of the frame start trigger.