Features AW00123402000
224 Basler ace USB 3.0
For more information about the pylon API and the pylon Viewer, see Section 3.1 on page 37.
For general information about auto functions, see Section 8.11 on page 209.
For information about Auto Function ROIs and how to set them, see Section 8.11.3 on page 211.
8.11.8 Using an Auto Function
1. Select an Auto Function ROI.
2. Assign the auto function you want to use to the selected Auto Function ROI.
3. Unassign the auto function you want to use from the other Auto Function ROI.
4. Set the position and size of the Auto Function ROI.
5. If necessary, set the lower and upper limits for the auto functions’s parameter value.
6. If necessary, set the target value.
7. If necessary, set the auto function profile to define priorities between auto functions.
8. Enable the auto function by setting it to "once" or "continuous".
For more information about the individual settings, see the previous sections that describe the
individual auto functions.
To use an auto function using Basler pylon: