Physical Interface AW00123402000
62 Basler ace USB 3.0
5.10.2 Factors Determining I/O Temporal Performance
A number of factors control the exact durations of propagation delays. The influence for some of
the factors is, however, ill constrained or unknown. As a consequence, generally valid and exact
quantitative assessments of propagation delays are impossible.
The following factors apply:
Factor IInfluencing Camera I/O
Propagation Delays
Input Output
Opto-isolated
IN
Direct-coupled
GPIOs
Opto-isolated
OUT
Direct-coupled
GPIOs
Operating temperature:
Unknown but temperature must
be within specified range; see
Section 1.8.1 on page 30.
º
º
Production spread:
Unknown
º
º
Aging (optocouplers):
Unknown
••
External I/O supply voltage:
Depends on application but must
be within specified ranges; see
Section 5.7 through Section 5.9.
••
º
Load resistance:
Depends on application
º
Load current:
Depends on application but must
be within specified ranges; see
Section 5.7 through Section 5.9.
º
Table 12: Factors Influencing Camera I/O Propagation Delays ( = major influence,
º
= minor influence)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler Camera and is the answer not in the manual?

Basler Camera Specifications

General IconGeneral
CategorySecurity Camera
BrandBasler
ResolutionVaries by model
Sensor TypeCMOS
Frame RateVaries by model
DimensionsVaries by model
WeightVaries by model
InterfaceGigE, USB 3.0
Lens MountC-Mount, CS-Mount

Related product manuals