Standard Features AW00097603000
194 Basler aviator GigE
The following parameters are examples of parameters that are included in each sequence set:
* This parameter is individually available for timer 1, timer 2, timer 3, and timer 4.
**This parameter is only available in auto sequence advance mode.
Sequence Set Configuration
Before the sequencer feature can be used you must populate the sequence sets with the parameter
values of the sequence parameters and store the sequence sets in the camera’s memory. Each
sequence set is identified by a sequence set index number starting from zero. After storing, the
sequence sets are available for use by the sequencer feature.
Some sequence advance modes require the storing of additional settings, for example, the total
number of sequence sets you want to use, the number of consecutive uses of a sequence set or
the source to control sequence set advance. For details about populating sequence sets and
making related settings see the sections below explaining the sequence advance modes.
Exposure Time Black Level
Enable Acquisition Frame Rate Reverse X
Acquisition Frame Rate Reverse Y
Width Digital Shift
Height LUT Enable
X Offset Color Transformation Value
Y Offset Color Transformation Matrix Factor
Center X Color Adjustment Enable
Center Y Color Adjustment Hue
Chunk Mode Active Color Adjustment Saturation
Chunk Enable Light Source Selector
Binning Horizontal Timer Delay*
Binning Vertical Timer Duration*
Pixel Format Timer Delay Timebase*
Test Image Timer Duration Timebase*
Gain Sequence Set Executions**
Processed Raw Enable
When the sequencer feature is enabled, the sequence parameter values of the
current sequence set cannot be read or changed using the pylon API or the pylon
Viewer. Only those sequence parameter values will be displayed that were active
before the sequencer was enabled. You will not be able to "see" the parameter
values set by the current set.
Make sure the sequencer feature is disabled when configuring sequence sets.