AW00097603000 Image Acquisition Control
Basler aviator GigE 63
If the camera is set for hardware frame start triggering, there are two modes of operation:
"timed" mode:
With the "timed mode", the Exposure Time Abs parameter will determine the exposure time for
each frame.
and "trigger width":
With the "trigger width" mode, the way that you manipulate the rise and fall of the hardware
signal will determine the exposure time.
The "trigger width" mode is especially useful,
if you want to change the exposure time from frame to frame, and
if you require exposure times that are longer than the maximum possible exposure time you
can set via the exposure time parameter.
You can use the sequencer feature as an alternative to the "trigger width" mode if you require
exposure times that are periodically changing from frame to frame. For information on the
sequencer feature, see Section 10.10 on page 192.