Baumer Web interface | 8
V1.0 | IDC200 Operating Manual 49
Input value Data type Measurement range Unit
BrightOnDark
Quality Text ISO 15416
Sorting Text Disabled
AutoLeftRightTopDown
LeftRightTopDown
LeftRightDownTop
-
Timeout Integer 1 - 2000 ms
TypesEanUpc Text EAN-13 Add-On 5
EAN-13 Add-On 2
EAN-13
UPC-A Add-On 5
UPC-A Add-On 2
UPC-A
EAN-8 Add-On 5
EAN-8 Add-On 2
EAN-8
UPC-E Add-On 5
UPC-E Add-On 2
UPC-E
-
TypeGS1 Text GS1 DataBar Omnidir
GS1 DataBar Truncated
GS1 DataBar Stacked
GS1 DataBar Stacked Omnidir
GS1 DataBar Limited
GS1 DataBar Expanded
GS1 DataBar Expanded Stacked
GS-128
-
TypesOthers Text 2/5 Interleaved
2/5 Industrial
Code 128
Code 93
Code 39
Codabar
MSI
Pharmacode
-
The process interface is capable of reading the following values:
Output value Data type Measurement range Description
Code Text - Read code