Baumer Web interface | 8
V1.0 | IDC200 Operating Manual 53
Input value Data type Measurement range Unit
NotEndsWith
expected value Characteristic -
Input source 1 Text None
Barcecode 1 – Code 1
Matrixcode 1 – Code 1
ExpectedCode
-
Input source 2 Text None
Barcecode 1 – Code 1
Matrixcode 1 – Code 1
ExpectedCode
-
The process interface is capable of reading the following values:
Output value Data type Measurement range Unit
Is Pass Tri-State — = cannot be evaluated
0 = invalid
1 = valid
-
8.4.1.5 Auxiliary tool: Quality Check
This Auxiliary tool is for quality evaluation of one or more read codes.
Auxiliary Tool Quality NOTE: Auxiliary tools can only use previously parameterized
measuring tools as input source.
n
Input source: Selection of the code to be evaluated
▪ All 1D-Codes - Code Qualities: all 1D codes (barcodes)
found are checked and the set Minimum quality is applied
to the worst code.
▪ All 2D-Codes - Code Qualities: all 2D codes (matrix codes)
are checked and the set Minimum quality is applied to the
worst code.
▪ Checks a specific parameterized measuring tool.
n
Minimum quality: Selection of quality level
▪ Quality level A - very good
▪ Quality level B - good
▪ Quality level C - satisfactory
▪ Quality level D - sufficient
▪ Quality level F - fail
Annex: Quality features for barcode and matrix code [}54]
The process interface allows for setting the following values:
Input value Data type Measurement range Unit
Minimum quality Text QualityLevelA
QualityLevelB
QualityLevelC
-