8 | Web interface Baumer
62 Operating Manual IDC200 | V1.0
n
Settings Reset: Reset of the sensor settings. This operation
will not reset the network settings.
n
Factory Reset
n
Reboot Sensor
8.6 Diagnostic data mode
This mode provides diagnostic data such as Temperature, Auto focus cycles and operating
time. Display refresh is every 2 seconds. The values can be exported as a .csv file via the but-
ton.
General Overview
Temperature
n
Current sensor temperature.
Auto focus cycles
n
Counts of performed Auto focus cycles.
NOTE: Counting the focus cycles considers autofocus and
manual focus.
Autofocus: Every autofocus performed will increase the
count by one.
Manual focus: Every other manually performed focus opera-
tion will crease the count by one.
Up time
n
Provides of the operating time since switch-on.
Total up time
n
Provides the total operating time.
Export diagnostic data
n
Saving the current data records as a .csv file.
Temperature (since Power-On)
Display is as curve diagram together with the minimum and maximum values.
Maximum
n
Maximum temperature ever since sensor power up.
Minimum
n
Minimum sensor temperature ever since sensor power up.
Alarm limit
n
Reaching this temperature will output an alarm.
Warning limit
n
Reaching this temperature will output a warning.
Temperature (Lifetime)
Display is by frequency distribution diagram together with the minimum and maximum values.
The display is scalable.
Maximum
n
Maximum sensor temperature ever.
Minimum
n
Minimum sensor temperature ever.
Scale values Display scaling in the diagram:
n
absolute
n
logarithmic
n
normalized