IPC@CHIP SC123/SC143
Hardware Manual V1.06 [18.02.2010]
©2000-2008 BECK IPC GmbH Page 27
Word read from 0xC01
Memory configuration:
0xC03
??
0xC02
56
0xC01
78
0xC00
??
e.g.
> I W C01
Figure 6-5: 16 Bit read access from C01
h
, CSBE = 0, Read = 0x5678
Byte read from 0xC01
e.g.
> I B C01
Figure 6-6: 8 Bit read access from C01
h
, CSBE = 0, Read = 0x55
PCS6#
RD#
A22:0
Address = 000C01
h
D15:0
78xx
BHE#
0
Address = 000C02
h
xx56
1
xxxx
PCS6#
RD#
A22:0
Address = 000C01
h
D15:0
55xx
BHE#
0