Commissioning
BEUMER stretch hood® S
46 BA-6090103-EN
19.08.09
How to switch on the power supply
Electrical energy
Switch on the power supply with the main switch on the outside of the control
cabinet. This procedure is described in the Operation chapter.
Pneumatic energy
The compressed-air system and the air service unit have been connected. The
input pressure required must be at least 1 bar higher than the output pressure.
The system should be ventilated slowly in order to protect the machine parts.
Switch on the compressed-air supply including the shut-off valve at the air ser-
vice unit.
How to set the operat-
ing pressure
1. Pull up the pressure setting button for release.
2. Turn the pressure setting button until the desired pressure is indicated.
3. For interlocking, press down the pressure setting button.
The pressure switch is set by the commissioning engineer.