CT-600-2 83
No. Description Param. page
on HMI
Default
value
Default
unit
67 Motor 1, 2, 3 current AI calibration factor A Comp./Motor 3 -
1, 2, 3
1.0
68 Motor 1, 2, 3 speed AO calibration factor A Comp./Motor 3 -
1, 2, 3
14.29
69 Motor 1, 2, 3 speed AO calibration factor B Comp./Motor 3 -
1, 2, 3
0.0
70 Oil system pressure drop high warning Oil System 1 2.0 bar
71 Oil system pressure drop high alarm Oil System 1 3.0 bar
72 Main oil filter pressure drop high warning Oil System 1 1.2 bar
73 Main oil filter pressure drop high alarm Oil System 1 2.0 bar
74 Booster oil pump pressure difference on Oil System 1 2.8 bar
75 Booster oil pump pressure difference off Oil System 1 3.3 bar
76 Enable/disable oil pump Oil System 1 OFF
77 Oil separator load high warning Oil System 1 0 m3/h
78 Oil separator load high alarm Oil System 1 0 m3/h
79 OS.A95 oil filter pressure drop high warning Oil System 1 1.2 bar
80 Oil temperature high warning Oil System 2 65 °C
81 Oil temperature high alarm Oil System 2 70 °C
82 Oil temperature low warning Oil System 2 40 °C
83 Oil temperature low alarm Oil System 2 15 °C
84 Oil separator temperature low warning Oil System 2 15 °C
85 Oil separator temperature low alarm Oil System 2 5 °C
86 Oil separator temp. heater level on Oil System 2 20 °C
87 Oil separator temp. heater level off Oil System 2 40 °C
88 PID regulator type PID 1 NONE
89 PID setpoint suction pressure 1 PID 1 4.3 bara
90 PID setpoint suction pressure 2 PID 1 4.3 bara
91 PID setpoint cold brine 1 PID 1 7.0 °C
92 PID setpoint cold brine 2 PID 1 7.0 °C
93 PID setpoint discharge pressure 1 PID 1 17.0 bara
94 PID setpoint discharge pressure 2 PID 1 17.0 bara
95 PID setpoint hot water 1 PID 1 45.0 °C
96 PID setpoint hot water 2 PID 1 45.0 °C
97 Min capacity output before start PID 1 10 %
98 PID KP suction pressure (P) PID 2 - 1 20.0 %/bar
99 PID TN suction pressure (I) PID 2 - 1 30 s