BIS 2.3 - Access Engine DMS - Data Management System | en 89
Bosch Sicherheitssysteme GmbH Installation manual F.01U.028.713 | V 2.3.0.1 | 2009.11
“Actions” menu
Figure 10.9 “Actions” menu
Restart counter If an error causes a process to be
terminated, the restart counter increases by
1 and the process restarted. Restarts are
attempted until the maximum permitted
number of restarts (restart limit) has been
reached.
Last start time Last start time of this process. This is only
different from the first start time if the
process has been restarted in the
meantime.
Error counter For diagnostic reasons, the master keeps an
error counter for each core system process.
Last stop time The last time this process was terminated;
only displayed if individual processes were
terminated and not the whole system.
Exit number Order number for the sequence of the
termination of processes from the process
description file.
Batch start time Start time of the batch processes.
Batch period Describes how the processes are started
periodically at different times:
DAILY: has to be started daily.
WEEKLY: has to be started weekly.
Table 10.2 Parameters displayed in the Process Control window