88 en | DMS - Data Management System BIS 2.3 - Access Engine
F.01U.028.713 | V 2.3.0.1 | 2009.11 Installation manual Bosch Sicherheitssysteme GmbH
Exit state The exit state can assume the following
values:
NORMAL: The process has been terminated
normally and all resources used have been
garbage-collected and released.
CRASHED: The process was not closed
normally.
KILLED: The process was closed by the
master. If the master cannot shut down the
process normally, for example, it must kill
the process.
Description Short description of the process.
Output mode The output mode specifies the outputs, that
is, the results of a process, such as traces or
error messages.
Parameter Parameters and options that are passed to
the process as program arguments, e.g.
trace level and output mode.
Trace level Traces are used to test the processes during
their development. The trace level specifies
which messages are displayed.
This value can be changed separately here
for each process without influencing the
default setting.
Restart limit If a process cannot be started, the master
tries to restart it - specifying an upper limit
restricts the number of restart attempts.
Wait for
Readyevent
The processes indicated expect messages
telling them that other processes have
started successfully.
Error reset The error counter is reset after the specified
time.
First start time Time of the last system start.
Table 10.2 Parameters displayed in the Process Control window