12 | Analog and Frequency Inputs
66/144 Manual_C_80 Bosch Motorsport
Physical limits
of channel
Enter physical limits
of the sensor
Choose data type
of the measurement
variable
Enable additional
online calibration
Enter name to auto-
matically create a
new measurement
sheet
7. Click ‘Finish’ when done.
8. Enter channel name and description.
9. Click ‘OK’ when done.
The channel is inserted into the C 80 Project Tree.
Channel is linked
to ANA06
Input pull-up resistor
is deactivated
Characteristic
curve for sensor
Adjustment
is enabled
Available measurements for channel:
Measurement label Function
raw_name mV value of sensor
raw_name_fi filtered mV value of sensor
name physical value of sensor
name_fi filtered physical value
Online definition of the curve is covered in chapter ‘Online calibration of measurement
channels [}80]’.
Note
Working with automatically created measurement sheets is explained in chapter ‘Setting
up an online measurement [}75]’.