LED
Color / flashing pattern
1)
Significance
Measures
Priority
Flashing red Communication error (F4xxx)
If necessary, read detailed state via "S‑0‑0095,
Diagnostic message"
Low
All warnings
Flashing blue Command error
Flashing red All errors (except F4xxx / F9xxx / E0800)
Read detailed state via "S‑0‑0095, Diagnostic
message" and carry out service function
Flashing yellow-
blue
Repair required
Blue ● AF (drive in control)
● Lb (supply unit in rectifier mode)
● LB (supply unit in voltage control)
● I LB (supply unit in current control)
● AH (Drive Halt)
Flashing blue ● Ab (drive ready for operation, power on)
● Bb (control section and power section ready
for operation, mains voltage available)
● charg (DC bus charging active)
Off Supply unit not switched on
Check 24 V supply and switch it on, if not yet done
Cable interrupted
Check cable and connector
Hardware defective
Replace hardware
1) Flashing pattern: One square corresponds to a duration of
250 ms; the arrow marks the end of a cycle; abbreviations on
the squares: WH = LED permanently lit white, YE = LED per‐
manently lit yellow, BU = LED permanently lit blue, GN = LED
permanently lit green, RD = LED permanently lit red, -- = LED
is off
Tab. 12-5: LED display for the states of the sub-device state machine and the
resource state machine
IndraDrive X Drive Controllers Power Sections XCS1, XMD1,
XMQ1
101/123
Description of the devices