EasyManua.ls Logo

Bosch Rexroth IndraDrive X - Page 121

Bosch Rexroth IndraDrive X
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sercos
LED: Color / flashing pattern
1)
Description
Prio
2)
Off
NRT mode (no Sercos communication)
3)
6
Permanently lit orange
CP0 (communication phase 0 active) 6
Flashing orange-green
CP1 (communication phase 1 active) 6
Flashing orange-green
CP2 (communication phase 2 active) 6
Flashing orange-green
CP3 (communication phase 3 active) 6
Permanently lit green
CP4 (communication phase 4 active) 6
Flashing orange-green
HP0 (hot-plug phase 0 active) 6
Flashing orange-green
HP1 (hot-plug phase 1 active) 6
Flashing orange-green
HP2 (hot-plug phase 2 active) 6
Flashing green
Transition from Fast forward to Loopback 5
Flashing red-orange
Application error
(sub-device/device error [C1D])
4
Flashing red-green
MST warning
4)
(S‑0‑1045, Sercos: Device Status [S‑Dev], bit15)
3
Permanently lit red
Communication error
(sub-device/device error [C1D])
2
IndraDrive X Drive Controllers Power Sections XCS1, XMD1,
XMQ1
105/123
Description of the devices
R911392532_Edition 01 Bosch Rexroth AG

Table of Contents