Fig. 9-16: Configuring the signal trigger in the oscilloscope
Fig. 9-17: Configuring the signal in the oscilloscope
After having completed the signal configuration, click on "Start". Then acti‐
vate the "Enable" checkbox in the "Drive-integrated command value genera‐
tor" dialog (see fig. 9-15 "Drive-integrated command value generator" on
page 114). The axis now moves at a defined velocity and period. All selected
signals are automatically measured by the oscilloscope.
DOK-MTXMIC-EASY*******-CO06-EN-P Bosch Rexroth AG 115/177
IndraMotion MTX micro Easy Setup for Standard Turning and Milling Machines
Commissioning the drives