47
Bosch Security Systems 10/22 BLCC615R
Solution 6000-IP
Quick Start Guide
System > TimeZones >
TimeZone Options
MENU 7-5-3
1 Invert Period Logic N
2 Master Edit Allowed N
3 Reserved N
4 Reserved N
5 Reserved N
6 Reserved Y
7 Reserved N
8 Reserved Y
System > Holidays >
Holiday Name
MENU 7-6-0
H o l i d a y 1 N a m e
Use the [] and [] keys to scroll cursor left and right.
Use the [0] – [9] keys or the [] and [] keys to scroll
characters, then press [OK] to save. Press [OFF] to clear
text from the current cursor position.
System > Holidays >
Start Stop Dates
MENU 7-6-1
Start 12am Stop 12am
01 Jan 01 Jan
DD MM DD MM
Use the [] and [] keys to move to the field then [] and
[] to change. Press [OK] to save or [MENU] to exit without
saving.
i
Note
Press [OFF] to disable the holiday.
System > System Options >
General Options
MENU 7-7-0
1 Display LAN Fail Y
2 Report LAN Fail Y
3 Alarm On LAN Fail N
4 Cannot Change Own PIN N
5 Extend LAN Fail (Enable when using CM430S) N
6 Monitor Default PINs Y
7 PIN Always Required N
8 Display Menu Numbers Y
(*** System Wide Parameter ***)
System > System Options >
Area Options
MENU 7-7-1
1 Area 1 Common N
2 First Open Last Close N
3 Reset Siren All Users Y
4 Power Up As Down Y
5 Fault ACK All Areas Y
6 Delay Trouble Beeps Y
7 Power Up Disarmed N
8 Ignore Trouble On Arm N
(*** System Wide Parameter ***)
System > System Options >
Keypad Idle Screen
MENU 7-7-2
(*** System Wide Parameter ***) 0 0
00 - No Idle Screen 02 - Time
01 - Date And Time 03 - Custom Screen
Use [] and [] keys or enter 0 - 3, then press [OK] to
program the keypad idle screen - Single option only.
System > System Options >
Keypad Hi/Lo Temp
MENU 7-7-3
0 0 0
˚C
0 0 0
˚C
Hi TEMP Lo TEMP
(*** System Wide Parameter ***)
Use [] and [] Keys To Program The High / Low Keypad
Monitor Temperature. Max = 50 / Min = 0.
System > System Options >
Installer Options
MENU 7-7-4
1 Report Installer N
2 Report Prog Change Y
3 Restrict Installer PIN N
4 Reserved N
5 Auto Exit Install 2hr Y
6 Auto Exit Service 2hr Y
7 Multi Tenant Mode N
8 Allow Defaulting Y
(*** System Wide Parameter ***)
System > System Options >
Language
MENU 7-7-5
0 - English 0
1 - Alternate Language
Enter digits 0 – 1 to program the language required, then
press [OK] to save.

Table of Contents