2-64
Confidential
Error code DF00
This error does not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
An unidentified error occurred.
Error code E000
An error occurred in the ROM check sum.
Error code E100
Program error
---
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Print Unable E0
Turn the power off and then back on again.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Print Unable E1
Turn the power off and then back on again.
Step Cause Remedy
1
Firmware install failure
Install the latest firmware.
2 Main PCB failure Replace the main PCB ASSY.