CHAPTER 4 DISASSEMBLY AND RE-ASSEMBLY
4-19
(7) Remove the bind B M3x8 Taptite screw from the guide plate stopper and remove the left
guide spring 2.
(8) Remove the side regist guide from the DX feed ASSY by releasing the hook at the bottom
side of the ASSY using a pair of long nose pliers.
NOTE:
ERROR 41 may occur if the left guide springs are not fitted correctly. See subsection 2.2
Service Calls in CHAPTER 6 for more information on ERROR 41.
Fig. 4-30
(9) Remove the left guide plate from the DX feed ASSY while pushing down the DX paper
actuator forward and then release the Drive gear 14 to remove the DX feed roller ASSY.
Taptite, bind B M3x8
Guide plate stopper
Left guide springs 2
(hook)
DX feed ASSY (Back side)
2
1
Side regist guide
DX feed ASSY
DX feed roller ASSY
DX paper actuator
DX feed ASSY
Left guide plate
Drive gear 14