■ Error code 6901
Some fuser unit errors occurred at power-ON or upon recovery from sleep mode.
Error code 6902
After the error was detected at the fuser unit, power was turned ON again and the error is 
being checked. (If power is turned OFF and ON after error code 6901 occurred, this code is 
displayed for about 15 minutes.)
Step Cause Remedy
1
Connection failure of a fuser unit 
harness
Reconnect the fuser unit harness.
2
Connection failure of the eject 
sensor harness
Reconnect the eject sensor harness.
3 Fuser unit failure Replace the fuser unit.
4 Eject sensor PCB failure Replace the eject sensor PCB.
5
Low-voltage power supply PCB 
failure
Replace the low-voltage power supply 
PCB.
6 Main PCB failure Replace the main PCB.
Note:
• Turn OFF the power switch. After the fuser unit has cooled sufficiently, turn ON the power 
switch again and leave the machine for 15 minutes. This problem may then be cleared.
• To release the fuser unit error after taking appropriate measures, enter the maintenance 
mode once and quit it with the function code 99.