T-code Valid from serial number Date Publication No.
815, 816 6051502 2008-08-21 261828-040
4:262 Error when Ergo cabin
tilted up.
Interrupted circuit in operator cabin output signal for upward
tilt.
Cabin tilt deactivated. Check the magnetic coil, electrical supply, contacts and wir-
ing harness. Check the output signal (K1:10) on the ACT.
4:263 Error on digital output sig-
nal 4.
Interrupted circuit in output signal for AUX 2.
AUX deactivated. Check the magnetic coil, electrical supply, contacts and wir-
ing harness. Check the output signal (X131:21).
4:264 Error on digital output sig-
nal 12.
Interrupted circuit in output signal for AUX 3.
AUX deactivated. Check the magnetic coil, electrical supply, contacts and wir-
ing harness. Check the output signal (X131:10).
4:265 Error on digital output sig-
nal 13.
Interrupted circuit in output signal for AUX 4.
AUX deactivated Check the magnetic coil, electrical supply, contacts and wir-
ing harness. Check the output signal (X131:24).
4:266 Error on digital output sig-
nal 14.
Interrupted circuit in output signal for AUX 1.
AUX deactivated Check the magnetic coil, electrical supply, contacts and wir-
ing harness. Check the output signal (X131:38).
4:267 Error when Ergo cabin
tilted down.
Interrupted circuit in output signal for downward tilt of Ergo
cabin.
Cabin tilt deactivated. Check the magnetic coil, electrical supply, contacts and wir-
ing harness. Check the signal (K1:2) on the ACH.
4:268 Error on digital output sig-
nal 11.
Interrupted circuit in output signal for AUX direction A.
AUX deactivated. Check the magnetic coil, electrical supply, contacts and wir-
ing harness. Check the output signal (X131:37).
4:269 Error on digital output sig-
nal 15.
Interrupted circuit in output signal for AUX direction B.
AUX deactivated. Check the magnetic coil, electrical supply, contacts and wir-
ing harness. Check the output signal (X131:11).
4:270 Error on MCU output signal
1.
Interrupted circuit in output signal for main lift valve.
Lift deactivated. Check the magnetic coil, electrical supply, contacts and wir-
ing harness. Check the output signal (X131:26).
4:272 Error on MCU output signal
3.
Interrupted circuit in output signal for mast reach valve.
Reach movement deacti-
vated
Check the magnetic coil, electrical supply, contacts and wir-
ing harness. Check the output signal (X131:41).
Code Name Description/possible causes
Event Action