4 – 56 Repair Manual RRE140/160/180/200/250 © BT
Functions and parameters
Height preselector, description of function
T-code Valid from serial number Date Publication No.
815, 816 6051502 2008-08-21 261828-040
4.9.6 Height programming
IMPORTANT:
Height programming requires that parameter 510 allow free access or
that the CAN key/TruckCom is connected.
There is storage space for 200 different pick up and deposit levels.
Once the user screen is displayed, press buttons 1 – 9 to remove the
height preselector screen:
From this screen, pressing the i-button makes the teach-in screen for
the height
preselector appear:
The CID screen displays a box containing the selected aisle and level.
The forks' present level is given under the box.
On the right are the pallet symbols for pick up and deposit, with the pro-
grammed heights shown underneath.
Plus/minus or numerical buttons are used to specify the level. When
the green button is pressed, the current height is stored for the selected
level.
The current height is saved as a pick up height, and the deposit height
is saved automatically as the difference for the current height as deter
-
mined by service parameter 378 for the Pick up/Deposit difference.
The new heights will be displayed under the pick up and deposit sym-
bols.
The deposit height can be programmed individually using the arrow
buttons. Using the arrow buttons, you can select the icon for deposit
height. Then you press the green button.
The deposit height must be within the minimum and maximum values
specified by service parameter 378. If the height is outside this interval,
it will not be saved and the buzzer emits a warning sound.
To leave the programming screen, press the C-button.