EasyManuals Logo

Burkert 2000 Assembly Instructions

Burkert 2000
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
22
Option: Hand wheel




Interrupt the control air and fluid infeed before modifying the
devices and reduce the pressure in the fluid system.
Interrupt supplies of control air and medium
.
Empty valve housing
.
Unscrew transparent cap
from actuator cover.
Screw out position indicator with Allan key (
WAF5 or WAF8).

Carefully lever the transparent cap off the hand wheel with
a suitable tool (cap is only pressed on, not threaded)
Check: • Setscrew
without locking paint (3 pcs.) are loose
• Pull rod is at lower stop
(may be adjusted with Allan key WAF5 or WAF8).
Screw hand wheel onto actuator cover, using flats on hand
wheel and counterbracing at valve
max. tightening torques: D-50, E-63, F-80 = 15 Nm
G-100, H-125 = 20 Nm.
Screw pull rod with Allan key (WAF5 or WAF8) onto actuator
and secure with Loctite 274.


The screws secured with locking paint shall not be
moved:otherwise perfect functioning will no longer be assured!
Securely tighten setscrews
without locking paint
(3 pcs, WAF2.5).
Test valve for function and leaktightness
To open, turn hand wheel anticlockwise


Insert o-ring carefully.
Do not use sharp objects.
Push on transparent cap
with O-ring .
english



Table of Contents

Other manuals for Burkert 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Burkert 2000 and is the answer not in the manual?

Burkert 2000 Specifications

General IconGeneral
Model2000
ManufacturerBurkert
Ambient Temperature-10 to +60 °C
Protection ClassIP65
Operating Temperature-10 to + °C
Seal MaterialFKM
Operating Pressure0- bar
Fluid Temperature-10 to + °C