14
Technical data
Identification on the device Certification Variable key
UL-recognized PU01
Measuring
Equipment
EXXXXXX
®
UL-listed PU02
6.2.3. Dimensions
→ Please refer to the technical data sheets regarding the
type 8032, available at: www.burkert.com
6.2.4. Material data
Part
in contact with the medium
Material
• Sensor-fitting
• Refer to the Operating Instructions
of the related sensor-fitting (S030)
→ Also see the material data of the type SE32, chap. 6.1.4,
page 12.
6.2.5. Electrical data of the 8032
→ See electrical data of the SE32, chap. 6.1.5, page 12.
Conformity to the Pressure Equipment Directive
→ Make sure the device materials are compatible with the fluid.
→ Make sure the pipe DN is adapted for the device.
The device conforms to Article 4, Paragraph 1 of the Pressure
Equipment Directive 2014/68/EU under the following conditions:
• Device used on a pipe (PS = maximum admissible pressure;
DN = nominal diameter of the pipe)
Type of fluid Conditions
Fluid group 1, Article 4,
Paragraph 1.c.i
DN≤25
Fluid group 2, Article 4,
Paragraph 1.c.i
DN≤32
or PSxDN≤1000
Fluid group 1, Article 4,
Paragraph 1.c.ii
DN≤25
or PSxDN≤2000
Fluid group 2, Article 4,
Paragraph 1.c.ii
DN≤200
or PS≤10
or PSxDN≤5000
UL-Certification
Finished products with variable key PU01 or PU02 are UL-certified
products and comply also with the following standards:
• UL 61010-1
• CAN/CSA-C22.2 n°61010-1
English
Type 8032 - SE32