F 24 (Closing delay time): after a closing command or after automatic closing, the M2 gearmotor lead delays its start compared to gearmotor
M1; the time is adjustable.
the delay time can be deactivated or adjusted from 1" to 25".
= 0 = Deactivated (default); 1 = 1 second; 2 = 2=(seconds .................. 25 = 25=seconds.
F 30 (Slow down speed): setting the time during motor slow downs.
= 0 = Deac
tivated; 1 = maximum speed; 2 = intermediate speed 3 = minimum speed.
F 34 (travel sensitivity): adjusts the obstacle-detection sensitivity during travel.
10 = maximum sensitivity; .................. 100 = minimum sensitivity (default).
F 35 (Deceleration sensitivity): adjusts the obstacle detection sensitivity when decelerating.
10 =
maximum sensitivity; .................. 100 = minimum sensitivity (default).
F 36 (Adjusting partial opening): adjusts the leaf opening of the second motor M2 as a percentage of the total travel
10 = 10% of the travel (default); .................. 80 = 80% of the run-cycle.
F 37 (Opening slow down point): adjusts the motor's beginning slow down point before the opening endstop.
T
he b
eginning slow down point is calculated as a percentage of the leaf's complete travel (see par. about illustrating the slow down and end-strike
areas and points)
10 = 10% of the travel; .................. 25 = 25% of the run-cycle (default); .................. 60 = 60% of the run-cycle.