8400-M022-O1 Rev K Model 190 Indicator
32
Set Gravity Constant
The Cardinal 190 Weight Indicator is equipped with an acceleration of gravity function which
means that it can be calibrated in one location and then adjusted to match the acceleration of
gravity at the location where it will be used.
SEtgC
With sEtgC displayed, press the TARE key. The display will change to CaLgC=.
Proceed to the CaLgC= parameter.
SEtgC?
With sETgC? displayed, press the TARE key. The display will change to no. Press the
Fn/ key to toggle to yes and press the TARE key. The display will change to CaLgC=.
Proceed to the CaLgC= parameter.
Otherwise, to skip the Set Gravity Constant setup, press the TARE key to advance to the
Sio?. prompt.
CALgC= (Calibrated Gravity Constant)
This is the acceleration of gravity value of the location where the scale was calibrated. Set
to 0 if calibrated at the location of operation or if gravity constants are not going to be used.
Press the TARE key to show the current setting. If the value displayed is acceptable,
press the TARE key to save it.
Otherwise, use the Fn/ and UNITS/ keys to enter a new value and press the TARE
key to save it
oPgC= (Operating Gravity Constant)
This is the acceleration of gravity value for the location where the scale will be operated.
Press the TARE key to show the current setting. If the value displayed is acceptable,
press the TARE key to save it.
Otherwise, use the Fn/ and UNITS/ keys to enter a new value and press the TARE
key to save it. Consult the factory Tech Support for the Acceleration of Gravity value for your
location.