8400-M022-O1 Rev K Model 190 Indicator
Fine Span Adjustment
IMPORTANT! The FSPAn (FSPAn?) mode requires a load of 10% of Capacity
on the scale before adjustments can be made.
F span
Fine Span Adjustment (from SETUP Prompt)
1. If Fine Span Adjustment is desired, with the SETUP prompt displayed, press the
UNITS/ key until the display shows the FSPAn prompt.
2. Place a calibrated test weight on the scale and press the TARE key.
3. The display will change to show the amount of the test weight, an F will be displayed to
the right of the annunciators and the annunciators will alternately flash off and on.
4. Press the Fn/ key to increase the span by 0.5 division OR press the UNITS/ key to
decrease the span by 0.5 division.
5. Press the TARE key to exit the Fine Span Adjustment and advance to the
Hires? prompt.
Fspan?
Fine Span Adjustment (after pressing TARE at last Print prompt)
1. With fspan? displayed, press the TARE key.
2. The display will change to no.
3. Place a calibrated test weight on the scale.
4. Press the Fn/ key to toggle to yes and press the TARE key.
5. The display will change to show the amount of the test weight, an F will be displayed to
the right of the annunciators and the annunciators will alternately flash off and on.
6. Press the Fn/ key to increase the span by 0.5 division OR press the UNITS/ key to
decrease the span by 0.5 division.
7. Press the TARE key to exit the Fine Span Adjustment and advance to the
Hires? prompt.