EasyManuals Logo

Cardinal 190 User Manual

Cardinal 190
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
8400-M022-O1 Rev K Model 190 Indicator
1
SPECIFICATIONS
Power Requirements:
100 to 240
V AC (50/60 Hz) at 0.4A Max.
Enclosure Type:
Thermoplastic
IP69K wall or desk-mount
Enclosure
Size:
9.4
” W x 6.4” H x 3.7" D
(
239mm W x 163mm H x 93mm D)
Operating Environment:
Tempera
ture: 14 to 104 ºF (-10 to +40 ºC)
Humidity: 90% non
-condensing (maximum)
Display:
Six
-digit, seven segment, 1.0" high Backlit LCD
Transducer
Excitation:
5.
15V DC
S
ignal Input Range:
0
.5 mV min. to 40 mV max. (with dead load boost)
Number of Load Cel
ls:
6
each, 350 OHM minimum resistance
Load Cell Cable Length:
1500 feet maximum.
30 feet maximum without sense lines
C
onsult factory for other requirements
Di
vision Value:
1, 2
, or 5 x 10, 1, 0.1, 0.01, 0.001 commercial
0 to 99,
non-commercial
Sensi
tivity:
NON-COMMERCIAL
NTEP
CANADA
0.15 uV/e
0.
5uV/e (Class III/IIIL)
0.
5uV/e (Class III/IIIHD)
Scale Divisions:
NON-COMMERCIAL
NTEP
CANADA
100 to 2
40,000
100
to 10,000 (Class III/IIIL)
100 to 10,000 (Class III/IIIHD)
Internal Resolution:
1 part in
16,777,216
Ta
re Capacity:
Scale Capacity
Sample Rate:
1 to 100 samples per second, selectable
Auto Zero Range:
0.5 or 1 th
rough 9 divisions
Weigh
ing Units:
Poun
ds, Ounces, Kilograms, Grams
Keypad:
Color
-Coded, Capacitive Touch-type, 7 keys
Stand
ard I/O:
(1) b
i-directional RS232

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cardinal 190 and is the answer not in the manual?

Cardinal 190 Specifications

General IconGeneral
BrandCardinal
Model190
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals