8400-M022-O1 Rev K Model 190 Indicator
1
SPECIFICATIONS
Power Requirements:
100 to 240
V AC (50/60 Hz) at 0.4A Max.
Enclosure Type:
Thermoplastic
IP69K wall or desk-mount
Enclosure
Size:
9.4
” W x 6.4” H x 3.7" D
(
239mm W x 163mm H x 93mm D)
Operating Environment:
Tempera
ture: 14 to 104 ºF (-10 to +40 ºC)
Humidity: 90% non
-condensing (maximum)
Display:
Six
-digit, seven segment, 1.0" high Backlit LCD
Transducer
Excitation:
5.
15V DC
S
ignal Input Range:
0
.5 mV min. to 40 mV max. (with dead load boost)
Number of Load Cel
ls:
6
each, 350 OHM minimum resistance
Load Cell Cable Length:
1500 feet maximum.
30 feet maximum without sense lines
C
onsult factory for other requirements
Di
vision Value:
1, 2
, or 5 x 10, 1, 0.1, 0.01, 0.001 commercial
0 to 99,
non-commercial
Sensi
tivity:
NON-COMMERCIAL
NTEP
CANADA
0.15 uV/e
0.
5uV/e (Class III/IIIL)
0.
5uV/e (Class III/IIIHD)
Scale Divisions:
NON-COMMERCIAL
NTEP
CANADA
100 to 2
40,000
100
to 10,000 (Class III/IIIL)
100 to 10,000 (Class III/IIIHD)
Internal Resolution:
1 part in
16,777,216
Ta
re Capacity:
Scale Capacity
Sample Rate:
1 to 100 samples per second, selectable
Auto Zero Range:
0.5 or 1 th
rough 9 divisions
Weigh
ing Units:
Poun
ds, Ounces, Kilograms, Grams
Keypad:
Color
-Coded, Capacitive Touch-type, 7 keys
Stand
ard I/O:
(1) b
i-directional RS232

Table of Contents