8400-M022-O1 Rev K Model 190 Indicator
119
Setup
Enter SETUP and proceed to the Options Setup.
option
With option displayed, press the TARE key. The display will change to show opt=.
Proceed to the opt= parameter.
opt?
With opt? displayed, press the TARE key. The display will change to no. Press the
Fn/ key to toggle to yes and press the TARE key. The display will change to opt=.
Proceed to the opt= parameter.
Otherwise, to skip the Options Setup, press the TARE key to advance to the fUnC?.
prompt.
oPt= (Option)
Press the TARE key to show the current setting. If the setting displayed is acceptable,
press the TARE key again to save it.
Otherwise, use the Fn/▲ key to toggle to a new setting and press the TARE key to save
it. Allowable values are:
0 = No Option Card Installed
1 = Serial Interface, Ethernet, Wi-Fi, or USB Option Card Installed
2 = not applicable
3 = not applicable
4 = Digital to Analog Converter Option Card Installed
rAnGE=
Press the TARE key to show the current setting. If the setting displayed is acceptable,
press the TARE key again to save it.
Otherwise, use the Fn/▲ key to toggle to a new setting and press the TARE key to save
it. Allowable values are:
0 = 4-20 ma
1 = 0-20 ma
2 = 0-24 ma
3 = 0-10 volts
4 = 0-5 volts
5 = -10 to +10 volts
6 = -5 to +5 volts