8400-M022-O1 Rev K Model 190 Indicator
65
Checkweigher
The Model 190 has logic level outputs that can be used to control peripheral devices used to
signal when the weight is within preset limits. The output state of the Checkweigher (before
reaching the preset weight) is defined in the section SETUP, the d out= (Digital Output)
parameter.
NOTE: These outputs are at logic level and cannot drive external devices directly.
Solid-state relays can be used to accept the logic level outputs from the 190 and in
turn, drive the external device.
With the Checkweigher function enabled during setup of the indicator, the function must be
activated before it can be used. Refer to the section Function Setup, the FUnC (FUnC?)
parameter to enable the Fn/ key Hold function.
NOTE: Only one of the functions Hold, Count, Peak Hold, Checkweigher, or Live
Weight can be active at a time.
Target Weight Setup
1. Press and hold the Fn/ key until the display blanks.
2. Once the display blanks, release the Fn/ key
3. The display will change to show the first function prompt.
4. Repeatedly press the TARE key until the Lo 1= prompt is displayed.
5. Press the TARE key once again.
6. The display will show the current value for the minimum acceptable weight for ID 1.
7. If the setting displayed is acceptable, press the TARE key to save it.
8. Otherwise, use the Fn/ and UNITS/ keys to enter a new value for the minimum
acceptable weight for ID 1.
9. When the desired weight value is displayed, press the TARE key to save it.
10. The display will change to show the Hi 1= prompt.
11. Press the TARE key again.
12. The display will show the current value for the maximum acceptable weight for ID 1.
13. If the setting displayed is acceptable, press the TARE key to save it.
14. Otherwise, use the Fn/ key and UNITS/ key to enter a new value for the maximum
acceptable weight for ID 1.
15. When the desired value is displayed, press the TARE key to save it.
16. The display will change to show the Lo 2= prompt.
17. Repeat steps 5 to 9 to set the value for the minimum acceptable weight for ID 2.
18. The display will change to show the Hi 2= prompt.

Table of Contents