8400-M022-O1 Rev K Model 190 Indicator
52
Fn/ Key Functions
The Fn/ key is used to select several additional functions that may have been enabled
during the setup and calibration of the indicator. Those functions include Hold, Count, Time
and Date, Peak Hold, Checkweigher, Live Weight, Weight Accumulation, and Backlight Color.
IMPORTANT! The Hold, Count, and Live Weight functions cannot be enabled if the
Legal-For-Trade option (LFt=yes) was selected during setup.
Also, only one of the functions Hold, Count, Peak Hold, Checkweigher, or Live
Weight can be enabled at a time.
Description of Fn/ Key Functions
Function
Display
Description or Setting
Hold
HoLd X
X will be 1 if enabled, 0 if disabled
Count
CoUnt X
X will be 1 if enabled, 0 if disabled
Time and Date
HH:MM A
HH=hours, MM=minutes, A for AM, P for PM
MM.DD.YY
(usa=yes)
DD.MM.YY
(
usa=no
)
MM=month, DD=day, YY=last two digits of year
Peak Hold
PhoLd X
X will be 1 if enabled, 0 if disabled
Checkweigher
Lo=
Minimum acceptable weight prompt
X
*
= minimum acceptable weight value.
*
When the value for Lo= is greater than 0, the
Checkweigher function is enabled.
Hi=
Maximum acceptable weight prompt.
This prompt is displayed, when the value for Lo= is
greater than 0.
X
= maximum acceptable weight value
Live Weight
Act X
X will be 1 if enabled, 0 if disabled
Weight
Accumulation
ACCU X
X will be 1 if enabled, 0 if disabled
Backlight Color
Colors
Backlight Colors for normal operation and
Checkweigher results